Medicines beginning with F

Fampridine

Fampridine 10mg capsules

No stability information

Stability notes for Fampridine 10mg capsules

There are no stability notes for this medicine.

Supplier

4-Aminopyridine 10mg capsules (Special Order)

Fampridine 10mg modified-release tablets

Incompatible

Stability notes for Fampridine 10mg modified-release tablets

Contains desiccant. Unsuitable.

Provenance

This compatibility recommendation is derived from Fampyra 10mg modified-release tablets (Biogen Idec Ltd).

Suppliers (5) of Fampridine 10mg modified-release tablets
Fampridine 10mg modified-release tablets (Accord-UK Ltd)
Fampridine 10mg modified-release tablets (Brown & Burk UK Ltd)
Fampridine 10mg modified-release tablets (Teva UK Ltd)
Fampridine 10mg modified-release tablets (Viatris UK Healthcare Ltd)
Fampyra 10mg modified-release tablets (Merz Pharma UK Ltd)

What the ratings mean

Compatible
Suitable for use. Keep in MCA for shortest possible time: no more than 5 weeks for non-airtight; 8 weeks for airtight. Use likely to be off-label.
Use with caution
Suitable with mitigations. Keep in MCA for shortest possible time: no more than 5 weeks for non-airtight; 8 weeks for airtight. Use likely to be off-label and supported by limited data.
Incompatible
Medicines under this category are not suitable for use in MCAs.
No stability information
These medicines have not been reviewed by SPS.